AQI and PM2.5 are different readings: AQI is an index summarising air quality, while a PM2.5 concentration measures the amount of fine particulate matter in the air. Under India's Central Pollution Control Board system, the highest pollutant sub-index determines the overall AQI. A PM2.5 concentration therefore cannot be read as the same number on the AQI scale.

This guide, checked on 28 November 2026, explains the CPCB method rather than reporting a fresh city reading. That distinction matters when comparing an air quality screenshot with an official bulletin: the pollutant, unit, place and averaging period all need to match before the numbers tell a useful story.

ReadingWhat it meansWhat to check
PM2.5 concentrationMass of fine particles per volume of airUnit, station and averaging period
PM2.5 sub-indexThat pollutant's position on the Indian AQI scaleThe CPCB concentration breakpoint band
Overall AQIThe highest valid pollutant sub-indexCategory, location and reporting time

What is the difference between AQI and PM2.5?

The CPCB's About National Air Quality Index document describes an index that converts complex pollution data into a number, description and colour. Its framework covers eight pollutants: PM10, PM2.5, nitrogen dioxide, sulphur dioxide, carbon monoxide, ozone, ammonia and lead. PM2.5 is one input to that framework, rather than another name for the final index.

For PM2.5, the concentration unit in CPCB's table is micrograms per cubic metre, written as µg/m³. The table uses a 24-hour average for this pollutant. An AQI value has no concentration unit. If a screenshot labels a number only as PM2.5 without saying whether it is a concentration or a sub-index, find that information before comparing it with the headline AQI.

The distinction becomes clear in CPCB's own example. A PM2.5 concentration of 45 µg/m³ corresponds to a PM2.5 sub-index of 75. Those two figures describe the same pollution input at different stages of the calculation. They are neither contradictory readings nor evidence that one service has necessarily made a mistake.

How is AQI calculated in India?

CPCB's calculation note says individual pollutant sub-indices are calculated using concentration averages and health breakpoint ranges. The averaging period is 24 hours for most pollutants in the framework, including PM2.5, and eight hours for carbon monoxide and ozone. Comparing an instantaneous concentration with a running average can therefore produce a misleading impression of disagreement.

After the pollutant values have been converted, the highest sub-index becomes the location's overall AQI. Consider an illustrative set of valid sub-indices: PM2.5 at 75, nitrogen dioxide at 60 and sulphur dioxide at 40. The overall AQI would be 75. It would not be the sum, 175, or the average of those three numbers. This is a calculation example, not a monitoring observation.

Nor does PM2.5 always determine the answer. If another monitored pollutant has a higher valid sub-index, that pollutant determines the overall AQI. This is why reading the prominent pollutant alongside the main number adds information that a colour alone cannot provide.

What do the Indian AQI categories mean?

Indian AQICPCB category
0-50Good
51-100Satisfactory
101-200Moderately polluted
201-300Poor
301-400Very Poor
401-500Severe

These are index bands. The PM2.5 concentration bands are different: CPCB places 0-30 µg/m³ in Good, 31-60 in Satisfactory, 61-90 in Moderately polluted and 91-120 in Poor. Copying the AQI thresholds directly onto a PM2.5 concentration would put that reading into the wrong category.

For public action, CPCB's broad guidelines say people should minimise travel during Very Poor or Severe AQI and use public transport. The index communicates conditions; it does not diagnose an individual's health or replace a medical assessment.

Why can an AQI reading be missing or change?

CPCB requires data for at least three pollutants to calculate overall AQI, with either PM2.5 or PM10 among them. It also states that at least 16 hours of data are necessary to calculate a sub-index. Individual pollutant sub-indices may still be shared when the information is insufficient for an overall AQI. A missing overall value should therefore never be interpreted as clean air.

The calculation note describes running averages: its 6 am example incorporates observations from 6 am the previous day to 6 am that day. In IST, a reading labelled 6 am on 28 November would describe that stated window, rather than conditions measured only at that instant. Always retain the date and time attached to a changing reading.

CPCB's limitations note also warns that analyser data feed into real time AQI without scrutiny and may not be for statutory purposes. Power interruptions, maintenance and data transmission problems can disrupt the flow. Before drawing a trend, compare the same location, index system and reporting period, and check whether data are complete.

For examples of dated bulletin reporting, see our reports on Delhi's 26 November AQI, Mumbai's 23 November bulletin and Delhi NCR's 17 November GRAP report. Each is a dated observation, so use its original timestamp when making a comparison.